Control requirements and modes: 1 the synchronous control mode of two motors is based on one as the main machine and the other as the slave machine.

2. The frequency converters used for synchronization all adopt a voltage of 0-10v for a given speed. We use no. 1 potentiometer as the main potentiometer, and no. 2 and no. 3 as the fine-tuning potentiometer.

Wiring steps:

1) respectively connect the 10V short connection and GND short connection of the two frequency converters, connect the no.1 pin of the main potentiometer to 10V and the no.3 pin of the main potentiometer to GND, connect the no.2 pin of the two fine-tuning potentiometers to the main potentiometer, connect the no.2 pin to AI1 and the no.3 pin to GND,

2) operation signals are connected to D11, COM respectively



Inverter parameter setting:

P0-02 command source selection, set to 1, terminal command channel

P0-03 main frequency source X is selected and set to 2 and AI1 terminals

P0-14 lower limit frequency, set as 0.4hz,

P0-17 acceleration time is set to 5S p0-18 deceleration time is set to 5S

Start the inverter, turn the main potentiometer to observe the frequency changes of the two inverters and see if the changes are regular. Revise the frequency by two fine-tuning potentiometers respectively, reduce the frequency by 5HZ, and then observe if the frequency is in accordance with the law. Release the operation key and the inverter stops running

Two points:

1) the 10V terminals of multiple inverters must be short-connected, or they will not work properly due to pressure drop

2) the synchronization control is not the same as the frequency, the basis of whether the synchronization is linear velocity


label

深圳變頻器,通用變頻器廠家,低壓變頻器廠家
Previous: Slitting machine solution 2019-10-15
Next:None

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標題-8.png 0755-81719517
未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號